7010
MMC number range exceeded
Definitions:
A fixed quantity of alarm numbers (100) is reserved for the compile cycles. This has been exceeded
when defining a new CC alarm. (The valid range is between 0 and 4999).
Reaction:
Alarm display.
Remedy:
Define the CC alarm numbers in the valid range from 0 to 4999.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
7020
Compile cycle alarm number has not been defined
Definitions:
The alarm ID used by the compile cycle manufacturer is not known to the system. This was not allo-
cated when the compile cycle alarms were generated.
Reaction:
Alarm display.
Remedy:
The alarm can have 2 possible causes:
- The alarm number has not been defined. A definition must still be made.
- The call parameter used is not the same as the one transferred by the NCK.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
7100
Compile cycles VDI area: %1 byte for inputs and %2 byte for outputs.
Maximum %3 bytes available.
Parameters:
%1 = String (machine data)
%2 = String (machine data)
%3 = Max. length for interface
Definitions:
The sum of the input and output bytes at the VDI user interface for the compile cycles exceeds the
maximum quantity of 400 bytes.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Set the machine data for dividing up the
VDI user interface of the compile cycles (DB 9) into input and output bytes in accordance with the func-
tions in the compile cycles. The maximum quantity of 400 bytes must not be exceeded. There are no
restrictions concerning the division into input and output bytes.
Program Con-
Switch control OFF - ON.
tinuation:
7200
Problem with externally linked compile cycle %1 %2
Parameters:
%1 = Description string
%2 = Additional information
Definitions:
Problem with loadable compile cycles
Example:
"Version_conflict_with_CCNCKInterface_Version"
Meaning: The interface version of the compile cycle is incompatible with the NCK version.
"Loader_problem_from_dFixup"
Meaning: Unresolved references are left over after loading of all compile cycles, for example as an
ELD file is missing.
Reaction:
Alarm display.
Remedy:
See function description of the compile cycle!
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
7201
Assertion error in %1 line %2
Parameters:
%1 = String (path with program name)
%2 = String (line number)
© Siemens AG, 2009. All Rights Reserved