[Channel %1: ] Block %2 Polynomials PO[XH], PO[YH] and PO[ZH] are
not permitted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Polynomials for the coordinates of a reference point on the tool (PO[XH], PO[YH], PO[ZH]) can only
be programmed, if interpolation type ORICURVE is active. If ORIVECT, ORIPLANE, ORICONxxx is
active, no polynomials can be programmed for coordinates XH, YH and ZH.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14139
[Channel %1: ] Block %2 Polynomial for angle of rotation PO[THT] is not
permitted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A polynomial for the angle of rotation of orientation (PO[THT]) can only be programmed, if the active
transformation supports it.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14140
[Channel %1: ] Block %2 position programming without transformation
not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Position information was programmed for an axis position but no transformation was active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14144
[Channel %1: ] Block %2 PTP movement not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The PTP G code was programmed for a movement other than G0 or G1.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation: