129931
%1: Min. %2 ETPD lists are required for the requested time determination
($MN_MM_PROTOC_NUM_ETPD_STD_LIST[%3])
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
%2 = Number of ETPD lists required
%3 = User index
Definitions:
Time measuring of the configured workpiece requires at least the specified number of ETPD lists.
Remedy:
Set general machine data $MN_MM_PROTOC_NUM_ETPD_STD_LIST[%3] of NCU %1 to value
%2.
129932
DAT: The configured NCU (%1) for part program %2 in channel %3 is
invalid.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
%2 = Name of the part program
%3 = Channel number
Definitions:
The specified combination of NCU, part program and channel is invalid for time measuring of the con-
figured workpiece.
Remedy:
Part program %2 can only be assigned to a channel in an NCU configured in NETNAMES.INI.
129933
DAT: The configured channel (%1) for part program %2 in NCU %3 is
invalid.
Parameters:
%1 = Channel number
%2 = Name of the part program
%3 = Name of the NCU according to NETNAMES.INI
Definitions:
The specified combination of NCU, part program and channel is invalid for time measuring of the con-
figured workpiece.
Remedy:
Correct the corresponding entry in the DAT file belonging to the workpiece.
129934
DAT: Part program %1 has been configured more than once.
Parameters:
%1 = Name of the part program
Definitions:
For time measuring of the configured workpiece, the specified part program is configured for several
channels.
Remedy:
Correct the corresponding entry in the DAT file belonging to the workpiece.
129935
NC configuration not yet determined.
Definitions:
Unable to determine the configuration of the NCs.
Remedy:
Ensure that communication to the NC has been activated and all machine data required for time mea-
suring have been set correctly.
129936
Initialization not yet executed.
Definitions:
An order has been sent to the ITS server although the server has not been initialized yet.
Remedy:
Execute your operation again later.
129937
Workpiece selection missing.
Definitions:
The ITS server has not yet received any DAT file for time measuring, or the contents of the DAT file
is faulty.
Remedy:
Select a workpiece for execution prior to executing a time measurement.
129938
Status of workpiece (%1) could not be determined.
Parameters:
%1 = Workpiece name
Definitions:
The state ?editable? of the DAT file or the workpiece could not be determined.
Remedy:
Restart communication to the NC, if required.
129939
Workpiece (%1) is currently being machined.
Parameters:
%1 = Workpiece name
Definitions:
The DAT file or workpiece is currently disabled.
Remedy:
Close the open DAT file or the corresponding workpiece in MCSE, if required.
129940
Error in workpiece (%1).
Parameters:
%1 = Workpiece name
© Siemens AG 2009 All Rights Reserved