Siemens Sinumerik 840D sl Diagnostic Manual page 392

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
26222
[Channel %1: ] Block %2: The names of the protection areas
$NP_PROT_NAME[%3] and $NP_PROT_NAME[%4] are the same
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Index of 1st protection area
%4 = Index of 2nd protection area
Definitions:
Two protection areas were assigned the same name. The names of the protection areas must be clear
and identifiable.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Rename one of the protection areas involved.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26224
[Channel %1: ] Block %2: The names of the protection area elements
$NP_NAME[%3] and $NP_NAME[%4] are the same
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Index of 1st protection area element
%4 = Index of 2nd protection area element
Definitions:
Two protection area elements were assigned the same name. The names of the protection area ele-
ments must be clear and identifiable.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Rename one of the protection area elements involved.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26226
[Channel %1: ] Block %2: Invalid protection area type in $NP_TYPE[%3]
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Index of protection area element
Definitions:
An invalid protection area type was indicated. The permitted protection area types are defined by the
machine date MD18898 $MN_PROT_AREA_3D_TYPE_NAME_TAB.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Indicate valid protection area type.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26227
[Channel %1: ] Block %2: CAD file not found: %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
Definitions:
A CAD file referenced with $NP_TYPE was not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the name in $NP_TYPE or load the CAD file of this name into the control.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-392
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved