CHAPTER 7 EXTERNALS AND CONTROLS
5.3 Control Panel
5.3.1 Removing the Control Panel
1) Remove the reader unit.
2) Open the front cover, and slide out the
pickup feeding unit to the front.
3) Remove the three screws [1], and detach
the front door switch cover [2].
4) Remove the six screws [3], and discon-
nect the connector [4]; then, detach the
control panel [5].
7-18 P
COPYRIGHT © 2001 CANON INC.
[2]
F07-503-01
F07-503-02
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[1]
[5]
[3]
[3]
[4]