CHAPTER 4 IMAGE FORMATION SYSTEM
6) Disconnect the connector [6], and re-
move the two screws [7]; then, detach
the pre-exposure LED assembly [8].
7) Loosen the five mounting screws [9],
and detach the blade support plate from
the cleaning blade.

7.11.3 Mounting the Cleaning Blade

When mounting the cleaning blade, be
sure that the side with the marking [1] will
be the face.
1) Push in the cleaning blade [2] until it
butts slightly again the rear.
4-80 P
COPYRIGHT © 2001 CANON INC.
[8]
[7]
F04-711-04
F04-711-05
[1]
[2]
F04-711-06
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[6]
[9]
No gap
Blade retaining
plate