1.2 Basic Sequence of Operations (laser exposure system)
WMUP
Laser scanner motor
(M15)*
Image leading edge
signal (PTOP)
Laser
BD signal (BD)
*: If silence mode has been selected in user mode, a switch-over to half-speed
COPYRIGHT © 2001 CANON INC.
Main power switch ON
195˚C
INTR
CNTR LSTR
STBY
rotation is made after a specific period of time during in-wait rotation.
F03-102-01 Basic Sequence of Operations
2000 2000 2000 2000
CHAPTER 3 LASER EXPOSURE SYSTEM
Original set/ADF opened
Start key ON
INTR
In-wait
rotation
CANON iR5000i/iR6000i REV.0 JUNE 2001
PRINT
LSTR
STBY
In-wait
rotation
3-3 P