3.2 Rated Outputs of the DC Power Supply

Output
Connector
Output voltage
tolerance
Rated output
voltage
Rated output
current
Level of activation
(overcurrent
protection)
Output
Connector
Output voltage
tolerance
Rated output
voltage
Rated output
current
Level of activation
(overcurrent
protection)
* However, the AC input must be 85 to 135 V for the 100-V model, and 187 to 264 V for
the 230-V model.
COPYRIGHT © 2001 CANON INC.
3VA1
3VA2
J4014-1
J4017-1
J4014-2
J4017-2
J4014-3
J4017-3
J4014-4
J4017-4
J4014-5
J4017-5
±3%
3.4V
9.0A
5.5 to 8.0A
T07-302-01
24VU1
24VU2
J4005-1
J4004-3
J4009-3
±5%
24.0V
15.0A
5.5 to 8.0A
T07-302-02
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 7 EXTERNALS AND CONTROLS
3VA3
3VB
J4003-7
J4015-1
J4015-2
J4015-3
+2%
-2.5%
3.5V
2.5A
4.0 to 8.0A
24VU3
24VU4
J4003-1
J4007-1
J4006-1
J4003-1
J4010-1
J4011-1
5V
12VU
J4003-5
J4003-3
J4004-1
J4003-4
J4008-1
J4009-1
J4016-1
J4016-2
±3%
±5%
5.1V
12.0V
4.5A
1.0A
1.0 to 5.0A
2.5 to 5.0A
24VA
J4013-2
+7%
-5%
24.0V
4.0A
5.0 to 8.0A
7-9 P