CHAPTER 3 IMAGE PROCESSING SYSTEM

5. CCD/AP PCB

5.1 Removing the CCD Unit

1) Remove the reader unit.
2) Remove the copyboard glass.
3) Move the No. 1 mirror base to the left
end.
4) Remove the reader left cover and the
reader front cover.
5) Remove the eight screws [1], and dis-
connect the connector [2]; then, detach
tje CCD shielding plate [3].
6) Remove the screw [4], and disconnect
the connector [5]; then, free the cable
from the cable clamp [6], and detach the
original sensor unit [7].
7) Remove the four screws [8], and dis-
connect the connector [9]; then, free the
flat cable [10], and free the two fixing
claws [11]. Thereafter, detach the CCD
unit [12].
3-12 R
COPYRIGHT © 2001 CANON INC.
[1]
[2]
[1]
F03-501-01
[4]
F03-501-02
[8]
[9]
[11]
F03-501-03
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[3]
[1]
[7]
[5]
[6]
[8]
[10]
[12]