Normal Sequence - Canon iR5000i Service Manual

Hide thumbs Also See for iR5000i:
Table of Contents

Advertisement

3.2.1 Normal Sequence

In normal sequence, the control will be as follows:
If the surface of the fixing upper roller is 75°C or lower (60 min from power-on).
Main power
switch ON
Wait indicator
Fixing motor
(M3)
Main heater
(H1)
100V
Sub heater (H2)
120/230V
Sub heater (H2)
215 ˚C
210 ˚C
205 ˚C
200 ˚C
195 ˚C
*1:For the iR6000i (100V model), the WMUPR period in H mode is increased by 1 min.
Control
temperature
COPYRIGHT © 2001 CANON INC.
Control panel
power switch ON
SLEEP
WMUP
Red
Ambient temperature
Initial multiple rotation
Standby
Start of printing
During printing
2000 2000 2000 2000
Start key
ON
WMUPR*1
STBY
INTR
Green
H mode
F06-302-01
H mode
195°C
200°C
200°C
203°C
T06-302-02
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 FIXING SYSTEM
PSTBY PRINT
LSTR
Red
M/L mode
M/L mode
205°C
210°C
210°C
212°C
STBY
6-13 P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir6000iImage reader-a1

Table of Contents