4.7 Paper Sensor

4.7.1 Removing the Claw Jam Sensor
1) Remove the fixing assembly from the
machine.
2) Remove the two screws from the lower
separation claw assembly.
3) Remove the internal delivery roller.
4) Remove the mounting screw [1], and
detach the sensor together with its sup-
port plate [2].
5) Disconnect the connector [3], and re-
move the snap-on assembly; then, de-
tach the claw jam sensor [4].
4.7.2 Removing the Internal Delivery Sensor
1) Remove the fixing assembly from the
machine.
2) Remove the two screws, and detach the
lower separation claw assembly.
3) Remove the internal delivery roller.
4) Remove the mounting screw [1], and
detach the sensor together with its sen-
sor support plate [2].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 FIXING SYSTEM
[1]
[2]
F06-407-01
[3]
[4]
F06-407-02
[2]
[1]
F06-407-03