Cisco Video Surveillance 3000 Series Configuration Manual page 49

Table of Contents

Advertisement

Chapter 4
Feature Setup
Table 4-8
Option
Alert Triggering Area
Triggered by
Actions
HTTP Notification Area
HTTP Server
URL Base
Port Number
User Name
Password
OL-32285-01
Alert Notification Window Options
Description
Check the desired check boxes to designate the alerts that trigger actions:
Video Loss—Alert is triggered if the IP camera loses input to its codec
sensor module.
Tamper—Alert is triggered when the camera detects tampering, if
camera tamper detection is configured as described the
Area"
rows in
Alert—Alert is triggered by any of the following:
An IP camera app is stopped, restarted, or uninstalled
The IP Camera app manager settings are restored to their factory
default values
An SD or MicroSD card inserted, removed, or formatted
The IP Camera is reboots continually
Check the desired check boxes to designate that actions that the IP camera
takes when the corresponding trigger occurs.
Email—Sends information about the alert in an e-mail message to the
designated recipient. You design the recipient and configure other
e-mail options in other fields in this window.
Output 1—Changes the state of the output 1 port on the IP camera as
defined in the Port window.
Syslog—Sends information about the alert to a designated Syslog
server.
HTTP—Sends information about the alert as an HTTP stream to a
remote system.
Identify the server to which HTTP messages are sent by choosing IP
Address or Hostname from the drop-down list and entering the IP address
or host name in the corresponding field.
Enter a string to be used as the prefix in the HTTP URL. The HTTP URL is
sent in this format:
http://<IP address>/<URL Base>?<system-provided-name-value-pairs>
where IP address is the IP address of the destination server, URL Base is the
string that you enter, and system-provided-name-value-pairs is information
about the event.
Enter the port number that receives messages on the primary server to which
HTTP messages are sent.
If authentication is required on the primary server to which HTTP messages
are sent, enter the user name.
If authentication is required on the primary server to which HTTP messages
are sent, enter the password.
Cisco Video Surveillance 3000 Series IP Camera Configuration Guide