Operator Maintenance; Console Specification And Characteristics - Honeywell LEVEL 6 Operation Manual

Series 60 computer system
Table of Contents

Advertisement

A detailed discussion of all the available I/O
Table 8-2. CONSOLE SPECIFICATIONS
commands can be found in the Series 60 (Level 6)
AND CHARACTERISTICS
Minicomputer Handbook, Order No. AS22.
OPERATOR MAINTENANCE
Operator maintenance includes such pre­
ventive maintenance as normal checking, cleaning,
operating considerations, etc., performed period­
ically on a routine scheduled basis. The purpose
of t he maintenance is to keep the console in the
best of operating conditions thereby reducing the
possibility of downtime.
The following list is a general guide to oper ­
ator maintenance:
o Always plug the printer into a 3-wire
grounded outlet.
o Ensure that all covers are closed and
secured during operation.
o Never operate the console without paper.
o Avoid leaning or placing objects on any
part of the console.
o Turn power OFF before replacing paper or
ribbon cartridge.
o No beverage should be on or near the
console.
o No food should be on or near the console.
o Keep outside covers clean and free of
debris.
o Clean and dust the inside areas of the print
mechanism.
CONSOLE SPECIFICATIONS AND CHARAC ­
TERISTICS
Table 8-2 is a summary of the specifications
and characteristics of the TWU91 0 I Keyboard
Typewriter Console.
KEYBOARD TYPEWRITER CONSOLE
8-6
Print speed:
Print format:
Character set:
Print ribbon:
Paper stock
Device interface:
Matrix font:
Physical dimensions:
Operating Considerations
Temperature
Range:
Gradient:
Humidity
Range
Pressure
Range
Power Requirements
30 characters per second.
10 characters per inch,
horizontally
6 characters per inch,
vertically.
64-character ASCII set.
Cartridge type, replace ­
able by operator.
Standard continuous
fanfold paper forms with
feed holes on each edge
-::
with or without margin
perforations; 7.62cm
(3.0 in) to 43.2cm (17
inch) form length:
10.16cm (4.Oin) to 38.1
cm (15 in) forms width
Each keyboard typewriter
console requires its own
Device-Pac (KCM91 0 1).
7 by 9 dot matrix; equiv­
alent to 10 point type.
19.05cm (7.5 in) height;
57.l5cm (22.5in)
width; 66.04 cm (26.0
in) depth.
10 to 30
0
C (dry bulb)
11
0
C per hour
10% RH to 90% RH
780 to 562mms of Hg
117Vac
+
10%-15%
SO/60Hz single phase
3 wire
208Vac
+
100/0-15%
SO/60Hz single phase
3 wire
220Vac
+
10%-15%
SO/60Hz single phase
3 wire
240Vac
+
10%-15%
SO/60Hz single phase
3 wire
AT04

Advertisement

Table of Contents
loading

This manual is also suitable for:

60 series level 6

Table of Contents