Honeywell LEVEL 6 Operation Manual page 33

Series 60 computer system
Table of Contents

Advertisement

-. .
-----------------------SECTOR1*THRUM(M=120R24)--------------------~
. .
~
SECTOR
SECTOR
MARK
MARK
t
GAP'
SW1
SW2
GAP3
I
BYTE 1
BYTE 2
BYTE 3
BYTE 4
WORD1
WORD2
*
SECTOR 1 SPECIFIED BY PRECEDING
INDEX MARK
Figure 4-4. Basic Track Fonnat
CONFIGURATION WORD A
TABLE 4-3. COMMAND REPERTOIRE
15
Function
Type
Command
Code
CYLINDER NUMBER
Output
09 (HEX)
IOLD (Output Address and Range)
CONFIGURATION B
OF
Output Offset Range
o
6 7
8
15
01
Output Control
RSU
I
TRACK
SECTOR
03
Output Interrupt Control
11
Output Configuration Word A
13
Output Configuration Word B
Figure 4-5. Configuration Words A and B
07
Task Word
by one after each data field sector during update
Input
OC
Input Range
read or write operations and will point numeri­
OE
Input Offset Range
cally to the next sector after completion of the
02
Input Interrupt Control
operation. Bit 7 of Configuration Word B speci­
10
Input Configuration Word A
fies the upper or lower surface of the selected
12
Input Configuration Word
B
platter. Bits 0-3,5, and 6 of Configuration Words
18
Input Status
A and B respectively are Reserved for Software
Use (RSU).
06
Task Word
Cartridge disk drive operation is implemented
26
1
Input Device - Identification
by two sets of instructions; the input and the
Code
output commands (see Table 4-3). A discussion of
CDU9101 - 2330
these commands
will
be found in the Series 60
1Por the Cartridge Dick Unit, CDU9102 - 2331
(Level 6) Minicomputer Handbook, Order No.
the device number is:
CDU9103 - 2332
AS22.
CDU9104 - 2333
CARTRIDGE DISK UNITS
4-4