Show Command - Cisco Prisma II Hybrid Amplifier Installation Manual

Hybrid amplifier
Table of Contents

Advertisement

Chapter 3 Operation Using CLI
Alarm Module
The argument module can be added to modify the scope of the command to include
only the active alarms in the range indicated by the current Module prompt.
The following sample dialog shows how this argument affects the response.
20/* MODULE> alarm module <Enter>
No active alarms found
SUCCESS!
20/* MODULE>
This response indicates that no alarms are currently among the modules installed in
chassis 20. Alarms that may exist in other chassis are not reflected.

Show Command

The show command (at the Module prompt) is used to display the values of
parameters specified by one of four following arguments: control, monitor,
alarmstate, or alarmparam. These arguments, in turn, are followed by the name of a
control (or monitor or alarm) to match against. This name can be the complete name
or a pattern that includes one or more wildcard characters (*).
Show Control
The following sample dialogs using the control argument show the use of both
complete names and wildcards, as well as the kinds of information returned.
*/* MODULE> show control enable <Enter>
MODID
20/05
20/06
20/07
20/09
20/13
SUCCESS!
*/* MODULE>
*/* MODULE> show control *serv* <Enter>
MODID
01/07
01/08
01/08
SUCCESS!
*/* MODULE>
Show Monitor
The sample dialog below shows the kind of information returned by the monitor
argument.
*/* MODULE> show monitor *pwr <Enter>
40
NAME
SETTING
UNITS
Enable
On (1)
Enable
On (1)
Enable
On (1)
Enable
On (1)
Enable
Off (0)
NAME
SETTING
UNITS
Service
Off (0)
ServiceA Off (0)
ServiceB On (1)