Chapter 3 Operation Using CLI
Important: To avoid possible system disruption, broadcast set commands are not
supported. This means that the set control command can only be applied to one
module (chassis and slot number) at a time. If a specific chassis and slot number are
not specified in advance, the CLI interpreter will disallow the command. In addition,
the name of the control to be changed must be explicit; no wildcard characters are
permitted.
The following example shows how a craft operator might use set control to disable
the module in slot 5 of chassis 20, and then use show control to confirm the change.
*/05 MODULE> module chassis 20 <Enter>
20/05 MODULE> set control enable 0 <Enter>
SUCCESS!
20/05 MODULE> show control enable <Enter>
MODID
20/05
SUCCESS!
20/05 MODULE>
This example shows what would happen if the operator had omitted the initial step
of specifying the chassis:
*/05 MODULE> set control enable 0 <Enter>
Error: This command can only be used at an explicit Chassis and Slot prompt
Set the chassis and slot to specific values before using this command
*/05 MODULE>
Set Alarmparam
The CLI can be used to change the parameters of alarms that do not shut down a
module. These alarms are the "user" alarms of types 1, 2, and 7. While a full
description of the various alarm types is outside the scope of this document, it is
important here to note that any attempt to change an alarm's parameter will only be
effective if that alarm is of type 1, 2, or 7.
The set alarmparam command is typically used in conjunction with the info
command to first learn about alarm type and status, and then change alarm status
where appropriate and allowed.
The following sample dialog shows the info command can be used to first learn
about all (*) alarms in Module 2006, i.e., the module installed in chassis 20, slot 06:
20/06 MODULE> info alarm * type majorlow minorlow majorhigh minorhigh <Enter>
MODID
20/06
20/06
20/06
20/06
20/06
20/06
20/06
20/06
SUCCESS!
20/06 MODULE>
46
NAME
SETTING
UNITS
Enable
0
NAME
TYPE MAJORLOW MINORLOW MAJORHIGH MINORHIGH
PsOk
6
N/A
OutPwr
1
-1
IntPs
6
N/A
Enable
6
N/A
LasTemp
3
-20
LasBias
1
-2
InPwr
1
-16
Service
5
N/A
N/A
N/A
N/A
-0.7
1
0.7
N/A
N/A
N/A
N/A
N/A
N/A
-15
20
15
-1
-0.001
-0.01
-5
45
25
N/A
N/A
N/A