Chapter 3 Operation Using CLI
The following sample dialog illustrates the use of these arguments.
*/* MODULE> show alarmparam *pwr minorhigh <Enter>
MODID
20/05
20/06
20/06
SUCCESS!
*/* MODULE>
Note:
The returned value of N/A shown above indicates that the alarm does not have
the requested parameter.
Some alarm values can also be changed by a craft operator or network
management system. See the set alarmparam command for details.
Show Module
This command is used to generate a list of information for specified modules that
will help with their physical identification.
The following is a sample craft operator dialog using show module to display
information for the modules in slots 3, 4, and 5 of all chassis in the ICIM domain:
*/* MODULE> slot [3-5] <Enter>
*/[03-05] MODULE> show module <Enter>
MODID
20/03
20/05
SUCCESS!
*/[03-05] MODULE>

Info Command

The info command (at the Module prompt) is used to display more detailed
information than is returned by using the show command. The command can be
followed by the argument control, monitor, alarm, or module, which, in turn, is
followed by one or more arguments further specifying the type of information to be
returned.
The details or characteristics that can be requested for each argument include the
following:
Argument
Alarm
42
NAME
MinorHigh
OutPwr
1
InPwr
5
MaxInPwr
N/A
MODTYPE
NAME
Prisma II
Power Supply 3 / Fan Tray
9x19dBm
Prisma II Hybrid Amp
Details
Hysteresis
Index
Label
Limitadjust
Majorhigh
SERIAL
^ABCDEFG
^AAG1AZI
Description
threshold hysteresis value
alarm number, starting at 1, in the list of alarms
name of the alarm
allowed if alarm is adjustable, not allowed if not
High Major threshold