Manual Activation Laser Timeout - Button Settings
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when the button is held down, and after it
is released. Set the length (in milliseconds) for a timeout by scanning one
of the following bar codes, then setting the timeout (from 1-65535 millisec-
onds) by scanning digits from the
Default = Button Hold In-Stand 5000 ms, Button Hold Out-of-Stand 5000
ms, Button Release In or Out-of-Stand 0.
Laser Timeout - Button Hold
In-Stand
Laser Timeout - Button Hold
Out-of-Stand
Programming
Chart, then scanning Save.
Laser Timeout - Button
Laser Timeout - Button
Release Out-of-Stand
Release In-Stand
4 - 11