Installing the Front Door and Air Intake Frame
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
To install the front door and air intake frame to the Cisco Nexus 7018 cable management system, follow
these steps:
Position the left door stopper (700-27454-01) on the middle of the left cable management assembly and
Step 1
fasten it with two M3x10 pan-head screws as shown in
in. lbs.
Figure 3-13
1
Left door stopper identified with an L on the
bottom of the base.
3
Screw holes on the cable management
assembly.
Position the right door stopper (700-27592-01) on the middle of the right cable management assembly
Step 2
and fasten it with two M3x10 pan-head screws as shown in
to 7 in. lbs.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
3-20
Attaching the Left Door Stopper
3
Chapter 3
Installing a Cisco Nexus 7018 Chassis
Figure
3-13. Tighten these two screws to 5 to 7
1
2
2
Two M3x10 screws that fasten the stopper to
the cable management assembly.
Figure
3-14. Tighten these two screws to 5
OL-18634-01