Power Specifications For The Cisco Nexus 7000 Series Devices; Power Requirements For Device Components - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Appendix A
Technical Specifications
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
Table A-3
Component
7.5-kW power supply unit
Mid-frame doors and frame
(optional)
1. The predicted mean time between failure (MTBF) is based on the Bellcore Methodology.
Table A-4
Component
Chassis
Supervisor module
48-port 10/100/1000-Ethernet I/O
module
48-port 1-Gigabit Ethernet I/O
module
32-port 10-Gigabit Ethernet I/O
module
Fabric module
Fan tray
6-kW power supply unit
7.5-kW power supply unit
Front door (optional)
1. The predicted mean time between failure (MTBF) is based on the Bellcore Methodology.

Power Specifications for the Cisco Nexus 7000 Series Devices

The number of power supplies that a Cisco Nexus 7000 Series switch requires depends on the quantities
and types of modules that you include in the switch chassis. the type of power supply unit that you are
using, and the power redundancy mode that you are using.
The following topics explain how to calculate the device power requirements and the amount of power
available for each type of power supply configuration mode:

Power Requirements for Device Components

To determine the power requirements of the Cisco Nexus 7000 Series switches, add the power
requirements of each of its components. For each component, multiply the number of its modules by its
maximum or typical power requirement. To find the quantities and power requirements for each Cisco
Nexus 7010 switch, see
7018 switch, see
OL-18634-01
Weights, Quantities, and MTBF for the Cisco Nexus 7010 Chassis Components
Weights, Quantities, and MTBF for the Cisco Nexus 7018 Chassis Components
Power Requirements for Device Components, page A-3
Power Supply Configuration Modes, page A-4
Table
A-5. To find the quantities and power requirements for each Cisco Nexus
Table
A-6.

Power Specifications for the Cisco Nexus 7000 Series Devices

Weight per Unit
Quantity
25.5 lbs. (11.6 kg) 2 to 3
0 or 1
Weight per Unit
Quantity
187 lbs. (85.0 kg)
1
10 lbs. (4.5 kg)
2
14 lbs. (6.4 kg)
1 to 16 (mix
of either or
both types
15 lbs. (7.7 kg)
of I/O
modules)
18.5 lbs. (8.4 kg)
7.5 lbs. (3.4 kg)
3 to 5
25.8 lbs. (11.7 kg) 2
18 lbs. (8.2 kg)
2 to 4
25.5 lbs. (11.6 kg) 2 to 4
0 or 1
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
1
MTBF
(Hours) per Unit
341,536
1
MTBF
(Hours) per Unit
117,858
79,725
74,373
74,742
33,652
421,088
276,352
341,536
341,536
A-3