Troubleshooting The Fan Trays; Troubleshooting The Supervisor Modules - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Chapter 7
Troubleshooting
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
Step 5
Verify that the power supply unit is functional by replacing it with another power supply (see the
"Replacing a Power Supply Unit During Operations" section on page
into the same AC source. If the Input and Output LEDs turn green on the replacement power supply unit,
contact Customer Service (see the
defective power supply unit.
If you are unable to determine the problem with the power supply or determine which power supply unit
has the problem, contact TAC.

Troubleshooting the Fan Trays

The following conditions indicate that there is a problem with one or more fan tray modules:
While the system is running, each fan tray module should be exhausting air and its STATUS LED should
be green, which indicates that all of the fans in that tray are running above the threshold speed.
For a listing of the fan tray LEDs and the conditions that they indicate, see
To troubleshoot a fan tray problem, follow these steps until the problem is resolved:
Check if the STATUS LED is flashing red or is not lit on each fan tray. If the LED is flashing red, at least
Step 1
one fan in the tray is running at a slow speed or not running. If the LED is not lit, no power is going to
the fan tray.
Check if the power supply units are providing power to the chassis components. See the
Step 2
"Troubleshooting the Power Supply" section on page
Step 3
Make sure that the fan tray is properly seated in the chassis by following these steps:
a.
b.
c.
d.
Call Customer Service and describe the conditions that you are seeing with the fan tray. See the
Step 4
"Contacting Customer Service" section on page

Troubleshooting the Supervisor Modules

The following conditions indicate a problem with one or more supervisor modules:
OL-18634-01
The FAN LED on the chassis is amber.
The STATUS LED on the fan tray is flashing red.
Loosen the captive screws on the fan tray until they are no longer in the chassis.
Place one hand on the handle for the fan tray and pull the fan tray part way out of the chassis.
Push the fan tray back into the chassis until it is fully seated on the midplane and make sure that
each captive screw on the fan tray is aligned with its hole in the chassis.
Securely tighten each captive screw (to 8 lb. in.) to the chassis.
The SUP LED on the chassis is amber.
The STATUS LED on a supervisor module is amber, red, or not lit.
The CMP STATUS LED on a supervisor module is amber or red.
An ACT LED on a supervisor module is not lit.
"Contacting Customer Service" section on page
7-2.
7-6.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide

Troubleshooting the Fan Trays

8-1) and plugging its power cords
7-6) to replace the
Table C-6 on page
C-6.
7-3