Table C-3
LED
Status
Link (for each
port)
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
C-4
I/O Module LEDs (continued)
Status
Description
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Red
The module has detected a slot ID parity error and will not power on or boot
up.
or
The module is not fully inserted, and it is not making a reliable connection
with the supervisor.
or
The module has failed diagnostic tests and has powered down.
Blinking
The device has just been powered on, and the module is resetting.
red
or
The module is resetting and both ejector levers are out.
or
The module has been inserted during the initialization process.
or
The module could not power up because of insufficient power.
or
An overtemperature condition has occurred. A major temperature threshold
has been exceeded during environmental monitoring.
Off
The module is not receiving power.
Green
The port is active (the link is connected and active).
Orange
The port is disabled by the operator or is not initializing.
Blinking
The port is faulty and disabled.
orange
Off
The port is not active or the link is not connected.