90
Minor Alarms report conditions that, under most circumstances will not
prevent transceiver operation. This includes out-of-tolerance conditions,
baud rate mismatches, etc. The cause of these alarms should be investi-
gated and corrected to prevent system failure.

Status and Informational Events

Status events indicate current states or conditions that are not errors.
They are used merely to indicate process functions (i.e.,
).
Process
Informational (Inform) events pertain to those items which have
occurred since bootup. They may or may not indicate an error, and they
do not show current conditions, just an event that occurred at some point
after boot-up (i.e., Event #32

Event Code Definitions

Table 15 contains a listing of event codes that may be reported by the
transceiver. The codes shown are a subset of a larger pool of codes used
for various GE MDS products. For this reason, the table does not show
a sequential listing of all code numbers. Only the codes applicable to
this product series are shown. This list is subject to change with product
revision.
Event
Event
Code
Class
Description
000
Major
Not currently implemented.
001
Major
Not currently implemented.
002
Major
Frequency not programmed.
003
Major
Authorization fault detected.
004
Major
RF synthesizer out-of-lock condition.
005
Major
Not currently implemented.
006
Major
Not currently implemented.
007
Major
Not currently implemented.
008
Major
Radio not calibrated. Factory calibration is required for proper
operation.
009
Major
DSP download fault.
010
Major
Not currently implemented.
011
Major
Not currently implemented.
012
Major
Receiver time-out. No data received within the specified
receiver time-out time.
013
Major
Transmitter time-out.
014
Major
Alarm Test.
015
Major
Not currently implemented.
068
Major
Excessive Ethernet traffic on interface.
SD Series Technical Manual
).
Booting Up
Table 15. Event Codes
Reprogramming in