Packet Settings
Media Access
Control
(AP menu shown)
48
COM1/COM2 Port Inter-Packet Gap
packet on the serial interface for radios operating in Packet Mode.
Too short of a time can cause serial streams to be combined into
one large packet instead of two smaller ones. Too long of a time
can effectively slow down the communications channel. The
Inter-Packet Gap is specified by the number of character times
(the time it takes to send an individual character).
Transparent RX Timeout (ms)
parameters for
COM1/COM2 Inter-Packet Gap
received over-the-air. It tells the radio how to build an Ethernet
packet based on a transparent data stream received over the radio
channel.
—Selects
Device Type
Access Point serves as the Controller of the RF network. Only
one radio is configured as an AP. Typically this is the "polling
master." A Remote is connected to end devices in the field (e.g.
PLC, RTU), and there can be any number of these in a network.
Each Remote must have a unique Unit Address, which is set on
SD Series Technical Manual
—Timing setting used to delimit a
—This setting is similar to the timing
, but it applies to data
,
, or
Access Point
Remote
Store and Forward
. An
MDS 05-4846A01, Rev. H