Configuring The Port Priority - Cisco 2950 - Catalyst Switch Configuration Manual

Software configuration guide
Hide thumbs Also See for 2950 - Catalyst Switch:
Table of Contents

Advertisement

Chapter 14
Configuring STP
Beginning in privileged EXEC mode, follow these steps to configure a switch to become the secondary
root for the specified VLAN. This procedure is optional.
Command
Step 1
configure terminal
Step 2
spanning-tree vlan vlan-id root secondary
[diameter net-diameter [hello-time
seconds]]
Step 3
end
Step 4
show spanning-tree detail
Step 5
copy running-config startup-config
To return the switch to its default setting, use the no spanning-tree vlan vlan-id root global
configuration command.

Configuring the Port Priority

If a loop occurs, spanning tree uses the port priority when selecting an interface to put into the
forwarding state. You can assign higher priority values (lower numerical values) to interfaces that you
want selected first and lower priority values (higher numerical values) that you want selected last. If all
interfaces have the same priority value, spanning tree puts the interface with the lowest interface number
in the forwarding state and blocks the other interfaces.
78-11380-10
Purpose
Enter global configuration mode.
Configure a switch to become the secondary root for the specified
VLAN.
For vlan-id, you can specify a single VLAN identified by VLAN
ID number, a range of VLANs separated by a hyphen, or a series
of VLANs separated by a comma. The range is 1 to 1005 when
the SI is installed and 1 to 4094 when the EI is installed.
(Optional) For diameter net-diameter, specify the maximum
number of switches between any two end stations. The range is
2 to 7.
(Optional) For hello-time seconds, specify the interval in
seconds between the generation of configuration messages by
the root switch. The range is 1 to 10 seconds; the default is 2
seconds.
Use the same network diameter and hello-time values that you used
when configuring the primary root switch. See the
Root Switch" section on page
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.