3. Set the tilt table to 10
out of range, repeat Steps 1 and 2 of this section.
4. Set the tilt table to 10
is out of range, repeat Steps 1 and 2 of this section.
5. Set the tilt table to 0
6. Proceed to Step R.
R. ARINC 429 ROLL OFFSET
1. Set the tilt table for 0
ROLL OFFSET page (see
2. Press the WxA to display brackets around the ROLL value. Adjust the TILT knob
for a ROLL value of 0.0 ± 1.0
3. Set the tilt table to 10
out of range, repeat Steps 1 and 2 of this section.
4. Set the tilt table to 10
of range, repeat Steps 1 and 2 of this section.
5. Set the tilt table to 0
6. Proceed to Step S.
S. Save Configuration
1. Press the Wx button until the MAINT FUNCTIONS menu is displayed.
2. Press the GND MAP button to move the select pointer to SAVE SETUP DATA.
See
figure
2-20A.
3. Press the WxA button to display the save option page. See
the WxA button again to initiate the save process.
If the save process is successful, COPY PASS will be displayed for five seconds
before the display returns to the ART 2000 MAINTENANCE page. See
20B.
If the save process is unsuccessful, COPY FAIL will be displayed. Try again.
Rev 7, July/2002
°
pitch up. The value should be 10.0U ± 1.0
°
pitch down. The value should be 10.0D ± 1.0
°
pitch. The value should be 0.0 ± 1.0
°
pitch and roll. Press the GND MAP button to display the 429
figure
2-19).
°
. Press the WxA button to deselect the brackets.
°
roll right. The value should be 10.0R ± 1.0
°
roll left. The value should be 10.0L ± 1.0
°
roll. The value should be 0.0 ± 1.0
00643I05.TDC
°
. If the value is
°
. If the value
°
.
°
. If the value is
°
. If the value is out
°
.
figure
2-20B. Press
figure 2-
RDR 2000
Page 2-33