FIGURE 2-11 TILT KNOB CALIBRATION FUNCTION
3. Adjust the TILT SETTING between 5 and 10 UP to increment the 400 HZ REF field
°
to 0.0 ± 1.0
(adjusting the TILT SETTING between 5 and 10 DOWN will decrement
the numbers). Upon reaching the desired setting, quickly adjust the TILT SETTING
to above 10° to lock in the setting. See
4. Proceed to Step G.
G. PITCH OFFSET
1. Adjust the GAIN knob for a GAIN POT setting between -17.5 and -19.5 (see
2-10). An 04 should be displayed in the AZIMUTH COUNT field
2. Check that the tilt table is set for 0
3. Adjust the TILT SETTING between 5° and 10° UP to increment the PITCH ANGLE
field to 0.0 ± 1.0
rement the numbers). Upon reaching 0
to above 10° to lock in the setting. See
4. Set the tilt table to 10
5. Set the tilt table to 10
6. Set the tilt table to 0
7. Proceed to Step H.
H. ROLL OFFSET
1. Adjust the GAIN knob for a GAIN POT setting between -14.0 and -16.0 (see
2-10). An 05 should be displayed in the AZIMUTH COUNT field
Page 2-24
NOTE
If the 400 Hz REF field is zero (0), and will not
change when the TILT knob is adjusted, check that
the correct gyro has been selected when program-
ming the Configuration Module.
°
pitch.
°
(adjusting the TILT SETTING between 5° and 10° DOWN will dec-
°
PITCH UP. The value should be 10.0 up ± 1.0
°
PITCH DOWN. The value should be 10.0 down ± 1.0
°
PITCH. The value should be 0.0 ± 1.0
00643I05.TDC
figure
2-11.
°
°
± 1.0
, quickly adjust the TILT SETTING
figure
2-11.
°
.
RDR 2000