BENDIX/KING
EQUIPMENT CONFIGURATION
EFIS EquipmentConfiguration - Selection for the ART 2000
Radar Type
Radar CTL PNL
OPERATIONAL CHARACTERISTICS CONFIGURATION
EFIS Configuration
Max Radar Scan Angle
*
Radar SDI
* This setting will be different for EACH SG-465 connected to the Radar.
2.4.3.1
Initial Procedures
The following procedures are accomplished by utilizing the controls on the EFIS Control Panel and
the Radar Control Panel.
A. Set the radar function selector to the TEST position. Press and hold the TST/REF button.
This places the EFIS system in self test mode.
B. When the display shows SELF TEST PASS, simultaneously press the HSI and ARC but-
tons. This must be done within five seconds of SELF TEST PASS being displayed. The
EFS 40/50 MAINTENANCE page should now be displayed. See
C. Press the RANGE DOWN button to display the EFIS MAINT FUNCTION page. See
2-6B.
D. Press the #2 bearing pointer button to move the select pointer on the display down to
ASCII TEXT PAGE.
E. Press the RANGE DOWN button to display the ASCII TEXT PAGE MENU. See
6C.
F. Press the #2 bearing pointer button (NEXT ITEM) to move the select pointer on the display
down to RADAR BUS.
G. Press the RANGE DOWN button to display the ART 2000 MAINTENANCE page. See
ure
2-6D.
Rev 7, July/2002
The EFIS symbol Generator (SG-465) must be the
correct configuration to operate with the ART 2000.
Below is a summary of equipment configuration.
PLEASE CONSULT THE EFIS MANUAL FOR
MORE INFORMATION.
- RDS 81/82/RDR 2000
- CP 466A or CP 466B (Set as appropriate)
- Selection for the ART 2000
-1 = 100 Degrees
-1 = Side 1 or
-2 = Side 2 or
-3 = Side 3
00643I05.TDC
NOTE
RDR 2000