B
B-110 Importing Density Measurements
For Windows computers, the file extension must be .cm1. For Mac
OS computers, the file type must be 'TEXT'.
Measurement data in EFI 34 and EFI 21 are paper-relative. For
other pages, if the first line corresponds to zero ink value, the
Calibrator assumes that the measurement data is absolute and
adjusts it to become paper-relative by subtracting the density
values of the first line from the remaining patches.
Example of 1D Status T density for EFI 34 patch
page
This file format is used to specify the Status T density
measurements of the EFI 34 patch page. The value in the first
column is the patch number. The first patch must be 1 and the last
must be 34.
#!EFI 3
# EFI ColorWise 2.0 Data
type: 1DST34
# Cyan
Magent Yellow Black
1 0.0300 0.0400 0.0200 0.0400
2 0.0600 0.0700 0.0800 0.0700
3 0.1000 0.1000 0.1000 0.1000
(...more data...)
33 1.6700 1.3400 0.8900 1.6700
34 1.7200 1.4300 0.9300 1.7500