A
A-108 Color Measurement Instruments
4. Insert the X-Rite Auto-Cal Strip into the 35mm slot on the front of
the X-Rite DTP32—arrow end first—until it stops or the
densitometer starts pulling the strip.
appears momentarily, followed by the density values and
Reading
CALIBRATION OK
MAIN MENU
If UNRECOGNIZABLE STRIP appears, repeat the process or try
cleaning the strip (see the X-Rite DTP32 Operating Manual).
Recalibrate the DTP32 at least once per month. For critical color,
calibrate the densitometer every time you calibrate the Fiery. The
DTP32 may also warn periodically that it requires calibration.
Sharp AR-C360P EFI Color Guide - 108
. The densitometer automatically returns to the
.