Install Internal Components and Field Replaceable Units
Figure 43: 650W/1000W AC Power Supply for C8300-2N2S-4T2X|6T
Table 11: 650W/1000W AC Power Supply for C8300-2N2S-4T2X|6T
1
Handle
3
Latch
5
Power
socket

Remove and Replace the AC and HVDC Power Supply (C8300-1N1S-4T2X|6T)

To remove an AC power supply from the C8300-1N1S-4T2X|6T, perform these steps:
Step 1
Read the safety warnings section of this document.
Step 2
If there is only one power supply in the system, shut down the device before removing the power supply.
Step 3
If there are redundant power supplies in use the device does not have to be shut down prior to replacing the power supply.
The power supply may be replaced while the device is in service.
Step 4
If in use, remove the strain relief securing the power supply cable to the power supply latch.
Step 5
Remove the AC power cord from the power socket.
Step 6
Depress the power supply latch and use the handle to pull the supply out of the device.
Remove and Replace the AC and HVDC Power Supply (C8300-1N1S-4T2X|6T)
2
Strain
relief
4
Status
LED