Figure 69 Audio Detection: NORMAL Tab

The red circles indicate where the audio alarms can be triggered when exceeding or
falling below the preset threshold.
Perform the following steps to configure Audio detection in the NORMAL tab:
1. Once the Audio detection window is opened, the current sound input will be
interactively indicated by a fluctuating white wave diagram.
2. Drag the Alarm level slider to a preferred location on the left slide bar.
3. Check Enable audio detection and click SAVE.
Note:

Figure 70 Audio Detection: PROFILE Tab

60
The volume numbers (0~100) on the left side of wave diagram does not
represent decibel (dB). Sound intensity level has already been mapped to preset
values. You can, however, use the real-world inputs at your installation site that
are shown on the wave diagram to configure an alarm level.
To configure this feature, you must not mute the audio in Setup Camera
Setup  Audio. The default of the camera can be muted due to the lack of an
internal microphone. An external microphone is provided by users.
Honeywell 30 Series IP Cameras User Guide