Casio DT-X200 Service Manual page 55

Handheld terminal
Hide thumbs Also See for DT-X200:
Table of Contents

Advertisement

4. Remove the UPPER-CASE-UNIT, paying attention to the FPC.
Note:
During repair work, be sure to cover the inner surface of the Touch Panel with the FILM/TP
(protective fi lm) to protect from dirt and scratches.
Code No.
10409754
Note on reassembling:
Remove the FILM/TP (protective fi lm) from the inner surface of the Touch Panel and, after
making sure that there is no dirt or scratches on the LCD and Touch Panel, assemble the
INNER-CASE-UNIT on the UPPER-CASE-UNIT.
INNER-CASE-UNIT
Parts Name
FILM/TP
Protective Film
(FILM/TP)
– 52 –
DT-X200/DT-X8
UPPER-CASE-UNIT
Specifi cation
RJC506040-001-V01