Casio DT-X200 Service Manual page 49

Handheld terminal
Hide thumbs Also See for DT-X200:
Table of Contents

Advertisement

3. Laser Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
Linear" from All Test MENU-6
screen.
1
4. 2D Imager Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
from All Test MENU-6 screen.
1
5. W-LAN Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
from All Test MENU-6 screen.
1
Operation
[5].Current - Laser/
Operation
[6].Current - 2D Scanner"
Operation
[7].Current - W-LAN"
Display
Display
Display
– 46 –
DT-X200/DT-X8
.
"
Test Details
Check if the current value is within
80 to 350 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.
.
"
Test Details
Check if the current value is within
200 to 550 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.
.
"
Test Details
Check if the current value is within
200 to 500 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents