3. Laser Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
Linear" from All Test MENU-6
screen.
1
4. 2D Imager Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
from All Test MENU-6 screen.
1
5. W-LAN Current
Use the same measurement connection as described in "1. Run Mode Current
No.
Adjust the DC power supply so
that the DC voltmeter reads 3.9 V.
"
Select
from All Test MENU-6 screen.
1
Operation
[5].Current - Laser/
Operation
[6].Current - 2D Scanner"
Operation
[7].Current - W-LAN"
Display
Display
Display
– 46 –
DT-X200/DT-X8
.
"
Test Details
Check if the current value is within
80 to 350 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.
.
"
Test Details
Check if the current value is within
200 to 550 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.
.
"
Test Details
Check if the current value is within
200 to 500 mA.
If OK.
The screen returns to the Menu
screen.
If out of range (Failure):
An error indication is displayed.
-> Pressing the "Enter" key
returns you to the Menu
screen.