Casio DT-X200 Service Manual page 14

Handheld terminal
Hide thumbs Also See for DT-X200:
Table of Contents

Advertisement

<
>
Power
Item
Main Battery
Backup Battery
Operating Time
* Normal temperature
* Brand-new battery
Backup Time
(Backup Battery only)
Backup Time
(Main Battery +
Backup Battery)
Main Battery Charge
Time
Backup Battery
Charge Time
Specifi cations
Lithium ion battery
Rechargeable lithium battery × 1
Standard Battery Pack
- Laser model: Approx. 10 hours
- 2D model: Approx. 9 hours
Large-capacity Battery Pack
- Laser model: Approx. 14 hours
- 2D model: Approx. 13 hours
Standard Battery Pack
- Laser model: Approx. 17 hours
- 2D model: Approx. 15 hours
Large-capacity Battery Pack
- Laser model: Approx. 25 hours
- 2D model: Approx. 20 hours
Standard Battery Pack:
Approx. 17 hours
Large-capacity Battery Pack
Approx. 25 hours
Standard Battery Pack
- Laser model: Approx. 8 hours
- 2D model: Approx. 7 hours
Large-capacity Battery Pack
- Laser model: Approx. 13 hours
- 2D model: Approx. 11 hours
RAM: 10 minutes
RTC: 72 hours or more
RAM: Approx. 72 hours
Standard Battery Pack:
Approx. 3 hours
Large-capacity Battery Pack
Approx. 4 hours
* When USB-PC is connected.
Standard Battery Pack:
Approx. 6.5 hours
Large-capacity Battery Pack
Approx. 8 hours
Approx. 4 days
Standard/Large-capacity
Built-in type
• CPU speed setting
= Automatic power saving mode
• Backlight = ON
• WEB Application mode
• Standby:Key input:Scan:Calculation:Wireless
= 15:5:1:2:2
• CPU speed setting
= Automatic power saving mode
• Backlight = ON
• WEB Application mode
• Standby:Key input:Scan:Calculation:Wireless
= 15:5:1:2:2
• Ratio of scan (NFC:Barcord = 9:1)
• Normal temperature
• Brand-new battery
• CPU speed setting
= Automatic power saving mode
• Backlight = OFF
• Standby:Key input:Scan:Wireless
= 20:1:1:1
• Normal temperature
• Brand-new battery
• CPU speed setting
= Automatic power saving mode
• Backlight = OFF
• Standby:Key input:NFC:Wireless
= 20:1:1:1
• JEITA A mode
• Wireless communication is always-on.
• Backlight = ON
• Scans two times in 10 seconds.
• Performs data transmission of 1KB.
• Normal temperature
• Backup battery is fully charged.
• After a main-battery remaining alarm occurs.
• Normal temperature
• USB Cradle, Ethernet Cradle and USB,
Charging Unit and AC adaptor
• Normal temperature
• USB and Charging Unit
• Normal temperature
• Time required to be fully charged with the Main
Battery is installed.
— 11 —
DT-X200/DT-X8
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents