Figure 10-7
2.
On the Tampering tab, in the Channel box, select the channel (camera) that you want to
configure video tampering detection settings for.
3.
Select the Enable check box to enable video tampering detection for the selected
channel.
4.
In the Sensitivity box, set the sensitivity level. Select a value between 1 and 6, with 6
being the highest sensitivity. The default setting is 3.
5.
To set the periods when video tampering detection is active, next to Period, click Set, and
then follow the steps listed in
6.
To set the actions that you want the system to initiate when a video tampering event
occurs, follow the steps listed in
7.
Click Apply to save your settings.
8.
To copy the settings to additional channels, click Copy, select the channels that you want
to copy the settings to, and then click OK.

Configuring Diagnosis Settings

You can configure the Diagnosis settings to alert you when the video is blurry, overexposed, or
the color changes.
To configure diagnosis settings
Go to Main Menu  Setting  Event  Video Detect  Diagnosis.
1.
To set up motion detection periods
To set up motion detection event actions
Configuring Event Settings
on page 86.