Performance Series HQA Digital Video Recorder Local User Guide
Table 8-3
Configuration
Type
Upper Limit
Show Message
Send Email
Record Channel
PTZ Activation
Delay
Tour
Snapshot
Video Matrix
104
Description
Select event type as High or Low, and set the upper and low humidity limit
respectively. For example, select event type as High and set upper limit as 28,
the alarm occurs when the temperature reaches 28.
Select event type as High or Low, and set the upper and low humidity limit
respectively. For example, select event type as High and set upper limit as 28,
the alarm occurs when the temperature reaches 28.
Click to enable a pop-up message on your local host PC screen to let you know
an alarm has occurred.
The system can send an email when an alarm is detected.
When you have enabled the Snapshot function, the system can also send an
image attached to the email. Go to Main Menu Setting NetworkEmail
to configure the email settings. See
The system automatically starts recording selected channels when a motion
detection alarm occurs.
Note You need to set the alarm recording period.
Go to StorageSchedule to configure the current channel for scheduled
recording. See
Configuring Record Settings
When PTZ activation is configured, the system can activate.
1. Click Set to open the PTZ Activation configuration interface.
2. Select a preset, tour, or pattern from the drop-down menu.
Click Save.
The system can delay recording for a specified amount of time after an alarm
has ended. Select from 10s to 300s.
Click to enable a tour to be triggered by an alarm. The system supports 1/8-
window tour. See
Configuring Display Settings
setup. On the Display Settings tab, when there are two tours enabled by
default, you can configure the system so an alarm triggers the system to
enable the alarm tours you configured here. If there is no alarm, then the
system uses the tour setup that was configured in the Display interface.
Click to enable the Snapshot function. Channel snapshots are taken according
to the schedule you configure. Alarm snapshots are taken when an alarm
occurs.
Click to enable. When an alarm occurs, the SPOT OUT port video (a 1-
Configuring Email Settings
on page 111.
on page
119
on page 78.
for tour interval