CL3/CL1
■ INITIALIZATION
To reset settings to the factory shipment state, execute "forced initialization" by turning on the power switch while holding down the
[STORE] and [INC] keys simultaneously.
When the forced initialization has been completed, the confi rmation message "Flash Memory Initializing Finished" will appear. Then
press the [CLOSE] key, and the normal screen appears followed by the version of DANTE. Wait until the ACCESS indicator at the
upper right turns off and that's the end of the procedure.
CL also has 2 types of initialization mode. They are "INITIALIZE ALL MEMORIES" and "INITIALIZE CURRENT MEMORIES".
They are available to users and can be used as necessary. To use these modes, turn on the power switch while holding down the [STORE]
key, and the special mode screen will appear. Then select the mode and execute initialization.
The following table shows types of memory initialized in above 3 initialization modes.
(○ marked memory is initialized)
Initialization
mode
CURRENT
SCENE
FORCED
INITIALIZATION
(Factory default)
INITIALIZE
ALL
MEMORIES
INITIALIZE
CURRENT
MEMORIES
Initialization
mode
Model
identifi cation
FORCED
INITIALIZATION
(Factory default)
INITIALIZE
ALL
MEMORIES
INITIALIZE
CURRENT
MEMORIES
* When the forced initialization (as when shipped from the factory) is executed, settings of the DANTE module will be as follows.
1. The device name of the DANTE module is reset to BLKN II xxxxxx and then renamed to Y001 YAMAHA CL x-xxxxxx after
restarting. The DANTE device name must be changed for correct connection of the CL series and I/O rack.
2. The network setting of the DANTE SECONDARY PORT is reset to [DAISY CHAIN].
* When the SECONDARY PORT setting or the IC of the CL series or I/O rack has been changed on the DANTE SETUP screen, it is
necessary to turn on the power again.
Changing SECONDARY PORT setting
1. Disconnect the Ethernet cable from the DANTE terminal or the CL series I/O rack.
NOTE
When changing the SECONDARY PORT setting, it is also necessary to change the cable connection between the CL series and I/O rack.
For example, if the setting is changed to DAISY CHAIN with cable connection for REDUNDANT setting as it is, it will be impossible
to send/receive the sound.
Be sure to disconnect the cable before changing the setting.
2. Check the REDUNDANT setting of the CL series and DIP switch setting of the I/O rack.
3. Turn on the power to the CL series and I/O rack again.
4. After waiting for about 1 minute, connect the Ethernet cable to the DANTE terminal of the I/O rack fi rst. Then, after waiting for
about 20 seconds, connect the Ethernet cable to the DANTE terminal of the CL series.
166
Memory type
MRAM
SETUP DATA
PORT TRIM
SCENE1-300
LIBRARY DATA
DATA
Dante Setup
-CONSOLE ID
DIO status
-SECONDARY
PORT mode
Memory type
FRASH ROM
FADER
NAME BL
CALIBRATION
CALIBRATION
Dante module
(Brooklyn II)
setting data
CH COLOR
USER
CALIBRATION
BITMAP