88 | Performance Series IR 1080p IP PTZ Camera User Guide

Configuring Time Task Actions

Time Task actions can be configured for the PTZ to perform during a specified time period. Up
to four time tasks can be programmed, each with up to six time periods.
1.
2.
3.
4.
5.
6.
7.
www.honeywell.com/security
Note
You must have a Preset, Tour, Scan or Pattern programmed before you can set it
up as a Power Up action.
Figure 6-9
Time Task Configuration Interface
Navigate to Setup
PTZ
Check the Enable check box to enable the Time Task function.
Select the Time Task to be programmed from the Time Task num drop-down list.
Select the Time Task action to perform at the set time, from Preset, Tour, Scan and
Pattern. After the action type is selected, use the drop-down list to select the Preset, Tour,
Scan or Pattern number to perform.
Note
You must have a Preset, Tour, Scan or Pattern programmed before you can set it
up as a Time Task action.
Enter an AutoHome value in the field from 1 to 3600 seconds. After the Time Task period
has ended, the PTZ camera will move back to its original position after the AutoHome time
has passed.
Click Period setting to open the Period Setup window.
Click Save to save your settings.