Mount the calibration weight (8kg) to the hook at the
bottom of the ergometer.
The actual strain gauge voltage (DMS-Volt) is shown and
should be in the given range.
SET stores the GAIN value
ATTENTION: The storage of the value needs
some seconds!
The successfull calibration is confirmed.
Remove the calibration weight.
Leave the menu by pressing ESC (top right key).
- 68 -
8
Kg calibration weight
c
alibration weight Mounted
Static Load Calibration
DMS-Volt:
S
tatic
eBike II, eBike II L, eBike II EL
(8
)
Kg
1676 mV
Calibr. succesfull
l
oad calibration finiShed