Error Code Bits Lre - GE eBike II Series Service Manual

Table of Contents

Advertisement

e
lre
rror Code BIts
Bit
Error
0
To high rotation
1
Load out of limit
2
DMS Offs. invalid
3
DMS Gain invalid
4
+24V out of range
5
+5V out of range
6
Brake not released.
7
Safety state mode
8
Setup not ready
9
CAN zykl. Timeout
2018112-069 Rev. F
Reaction
Display / Info
Warning
Warning
Safety shut down
Safety shut down
Internal error
Safety shut down
Safety shut down
Safety shut down
Internal error
Safety shut down
eBike II, eBike II L, eBike II EL
Troubleshooting
none
- advise user to cycle less than 130 rpm
- advise user to cycle between
30 and 130 rpm
- perform static calibration
- perform static calibration OFFSET
- if error persists:
replace strain gauge
- perform static calibration GAIN
- if error persists:
replace strain gauge
- check power supply
- check connections:
power supply to LRE
cable ZME <-> LRE
(or ZME <-> BDE
BDE <-> LRE)
- restart eBike (OFF / ON)
- if error persists: replace LRE
- check connections:
LRE <-> brake
LRE <-> strain gauge
- perform static calibration
- restart eBike (OFF / ON)
- if error persists:
replace BDE
- restart eBike (OFF / ON)
- if error persists:
check cable ZME <-> LRE
or BDE <-> LRE
- replace LRE
- restart eBike (OFF / ON)
- if error persists:
check cable ZME <-> LRE
or BDE <-> LRE
- replace LRE
- 135 -

Advertisement

Table of Contents
loading

Table of Contents