Error Code Bits Mae - GE eBike II Series Service Manual

Table of Contents

Advertisement

e
Mae
rror Code BIts
Bit
Error
0
Error seat sensor
1
Seat no movement
2
Wrong cabling
3
not used
4
+24V out of range
5
not used
6
not used
7
Safety state mode
8
not used
9
CAN zykl. Timeout
2018112-069 Rev. F
Reaction
Display / Info
Module is switched off
Internal error
Module is switched off
Internal error
Module is switched off
Internal error
Warning
Module is switched off
Internal error
Module is switched off
Internal error
eBike II, eBike II L, eBike II EL
Troubleshooting
- check cable sensor <-> MAE - -
- check cable motor <-> MAE
- if error persists:
replace seat motor
- check cable sensor <-> MAE - -
- check cable motor <-> MAE
- if error persists:
replace seat motor
- check cable sensor <-> MAE
- check cable motor <-> MAE
- replace cables
- check power supply
- check connections:
power supply to LRE
cable LRE <-> MAE
- replace MAE
- restart eBike (OFF / ON)
- if error persists: replace MAE
- restart eBike (OFF / ON)
- if error persists:
check cable LRE <-> MAE
- replace MAE
- 137 -