Wiring for Module Fault Relay
You may wire and program the module's fault output trigger for fail-safe mode (see the
question "FLT REL ON Y/N").
To sense a module fault at the control panel, make connections as shown in Figure 2-6,
including the proper EOL resistor required by the control.
A 24 hour supervisory zone must be assigned on the control panel, with the GSMHS's fault relay wired to
UL
that zone.
Figure 2-6. Wiring the GSMHS Fault Relay to a Control Panel Zone for Normally Closed Fault
Power Connections and Options
Powering the Communication Module
Primary power for the GSMHS is provided by the AC plug-in transformer. For ECP
communication, you must also connect the +12VDC AUX voltage output of the control panel
(9.6V-13.8V typical) (see Figure 2-7).
In all installations, TB1-4 GND must be connected to ground (AUX –) on the control panel.
NOTE:
12V AUX
GND
ZONE IN (+)
CONTROL PANEL
12V AUX
-
AUX
CONTROL PANEL
Figure 2-7. Powering the GSMHS
When calculating the total load on the auxiliary power output of the control panel, budget 10mA
for the GSMHS when using ECP mode.