GSMHS Installation and Setup Guide
PROMPTS
26
Open/Close Zone
(0)_
Zn1 Trigger Type
27
(V+)_
Restore Zn1 Y/N
28
(Y)_
29
Delay Zn1 (secs)
(00)_
Rpt Zn1 ONLY if
30
Armed (N)_
Invert Zn2 Y/N
31
(N)_
Restore Zn2 Y/N
32
(Y)_
Delay Zn2 (secs)
33
(00)_
Rpt Zn2 ONLY if
34
Armed (N)_
Zn3 Trigger Type
35
(V+)_
Invert Zn3 Y/N
36
(N)_
37
Restore Zn3 Y/N
(Y)_
3-14
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
Enter the zone number to be used for
Zone Trig:
open/close (arm/disarm) reports. This zone
[3-7]
assignment must be unique from the Telco
4204: [1-4]
zone selected in Prompt 25.
Zone Trigger Mode: If any zone is
2-4204:
programmed for "report only if armed,"
[1-8]
zone 7 cannot be used.
[0] = not
4204 Mode: If any zone is programmed for
used
"report only if armed," zone 4 cannot be
used as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel
to the open/close zone.
 (EOLR)
Selects the triggering method for this zone
input.
 (V+)
 (V–)
Press the [space] key to scroll through choices.
[Y], [N]
Enables restore reporting for zone 1.
[01-15]
Defines the reporting delay in seconds for
zone 1.
[00] = no
delay
[Y], [N]
Reports alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 1.
[Y], [N]
Inverts the alarm and normal states of the
zone 2 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 2.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 2.
[00] = no
UL: Must be set to "00."
delay
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
 (EOLR)
Selects the triggering method for this zone
 (V+)
input.
 (V–)
Press the [space] key to scroll through choices.
[Y], [N]
Inverts the alarm and normal states of the
zone 3 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 3.
UL: Must be set to "Y."