Setup & Operation 8. Memory Port
8.2.2 Adoptable USB Memory
Use USB memory that meets following conditions.
- USB2.0 supported
- Without security function
- No installation of a driver or software is necessary for Windows 7, Windows 8, or
8.3 Controller Status Storage Function
8.3.1 Controller Status Storage
■ Controller status storage function is available at any time and in any Manipulator
status after starting the Manipulator.
However, operations form the console including stop and pause are not available
while executing this function.
Also, this function influences the Manipulator cycle time and the communication
CAUTION
with EPSON RC+ 7.0. Other than only when it is necessary, do not execute this
function when operating the Manipulator.
Use this procedure to save the status of the Manipulator to USB memory.
(1) Insert the USB memory into the memory port.
(2) When the Manipulator status storage is completed successfully, the LED of TEACH,
(3) Remove the USB memory from the Manipulator.
NOTE
- USB memory with LED is recommended to check the status changes.
- When storage is executed during Motor ON status, it may fail to store the status. Use
another USB memory or execute the storage during Motor OFF status.
72
USB memory with password input function cannot be used.
Windows 10, Linux.
(For supported operating systems for the EPSON RC+ 7.0, refer to Setup &
Operation 2.5 System Example.)
When the data transfer starts, the LED of TEACH, AUTO, and PROGRAM starts
blinking. Wait until the LED status changes.
(The data transfer time varies according to the data size such as of the projects.)
AUTO, and PROGRAM are turned ON for two seconds. Note that the LED of
ERROR turns OFF even in the error status.
If it ends in failure, the LED of ERROR, TEACH, AUTO, and PROGRAM are turned
ON for two seconds.
VT Rev.1