Honeywell AlarmNet 7847i-E Installation And Setup Manual page 48

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

7847i/7847i-E Installation and Setup Guide
LED COLOR
GREEN
YELLOW
RED
an Unregistered 7847i/7847i-E Status Display in Normal Operating State(B)
The sequence below illustrates LED operation when 7847i/7847i-E transmits a message.
Figure 14. LED Sequence for a Registered 7847i/7847i-E Message Transmission
A-2
Table 6. Status Display Operation
LED LABEL
STATUS
FAST BLINK – Download session with Compass in progress.
MESSAGE
FAULT
STATUS, GREEN
MESSAGE, YELLOW
FAULT, RED
Figure 13. A Registered 7847i/7847i-E Status Display (A) and
STATUS, GREEN
MESSAGE, YELLOW
DESCRIPTION
7847i-E
ON – 7847i/
is NOT registered with AlarmNet or
7810iR-ent if Private LAN is enabled.
7847i-E
OFF – 7847i/
is registered with AlarmNet or 7810iR-ent if
Private LAN is enabled.
SLOW BLINK – In unison with yellow LED – registration in
progress.
ON – Message transmission pending.
QUICK PERIODIC BLINK – Normal.
FAST BLINK – Message waiting for network ACK.
SLOW BLINK – Idle, power abnormal.
– In unison with green LED – registration in
progress.
ON – No contact with the network.
OFF– Normal.
SLOW BLINK – Loss of communication with the panel (ECP fault).
FAST BLINK – No network contact AND loss of communication
with the panel.
A
MESSAGE, YELLOW
1
2
FAULT, RED
B
STATUS, GREEN
FAULT, RED
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alarmnet 7847i

Table of Contents