7847i/7847i-E Installation and Setup Guide
1.
Prompts 12-18 apply only if Private LAN was selected in Prompt 11.
2.
Prompts 14-16 apply only if Prompt 14: Alarm Delivery is set to "Fail to CS IP2".
PROMPTS
En.Priv.LAN: Y/N
11
(N)
CS IP:
12
255.255.255.255
CS Port:
13
(80)
Alarm Delivery:
14
Only One CS IP_
Secondary CS IP:
15
255.255.255.255
Second CS Port:
16
(80)
IP2 Supervision
17
30 Day_
Installation Key:
18
**********_
3-12
Important Information Regarding Private LAN mode (7847i-E only).
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
Applies only to 7847i-E. Press [Y] to enable alarm
[Y], [N]
delivery via a Private LAN to a 7810iR-ent
receiver.
Press [N] to enable alarm delivery through
AlarmNet and go to Prompt 20: Primary City ID.
12 digit:
Enter the 4-part primary CS IP address of the
xxx.xxx.xxx.xxx
7810iR-ent receiver at the reporting center to
which this device will report. The four parts of
the address must be separated by spaces.
NOTE: This entry CANNOT be left as
"255.255.255.255". It MUST be programmed with
a valid IP address.
[80]
Enter the Central Station Port Number.
NOTE: The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
Select the "Only One CS IP" option, if only one
[Only One CS
Central Station IP address is desired and go to
IP]
Prompt 18: "Installation Key".
[Fail to CS
IP2]
Select the "Fail to CS IP2" option, if a secondary
Central Station IP address is desired.
12 digit:
Enter the 4-part secondary CS IP address of the
xxx.xxx.xxx.xxx
7810iR-ent receiver at the reporting center to
which this device will report. The 4-parts of the
address must be separated by spaces.
NOTE: This entry CANNOT be left as
"255.255.255.255" if using the Secondary CS IP.
It MUST be programmed with a valid IP address.
[80]
Enter the Central Station Port Number.
NOTE: The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
• 30 Day
If 30 Day or Daily is selected, the 7847i-E will
send a test alarm to the second CS IP within that
• Daily
interval.
• Full Rate
If Full Rate is selected, a status message is sent
None
to the second CS IP at the same rate as the
regular Supervision Interval (Prompt 27).
NOTE: The second 7810iR-ent must be
programmed to supervise subscribers in order to
generate the communication failure.
Press the [space] key to scroll through the choices.
[0-9]
Enter the 10-digit Installation Key necessary for
communication with 7810iR-ent. If the key entry
is invalid, the prompt is repeated. See the
Installation Key paragraph in Section 1 for more
information.