Honeywell AlarmNet 7847i-E Installation And Setup Manual page 32

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

7847i/7847i-E Installation and Setup Guide
PROMPTS
Restore Zn3 Y/N
47
(Y)_
Delay Zn3 (secs)
48
(00)
Rpt Zn3 ONLY if
49
Armed (N)_
Zn4 Trigger Type
50
(V+)_
51
Invert Zn4 Y/N
(N)_
52
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
53
(00)
Rpt Zn4 ONLY if
54
Armed (N)_
Zn5 Trigger Type
55
(V+)_
Invert Zn5 Y/N
56
(N)_
Restore Zn5 Y/N
57
(Y)_
Delay Zn5 (secs)
58
(00)_
Rpt Zn5 ONLY if
59
Armed (N)_
Enable Zn6 Y/N
60
(N)_
Zn6 Trigger Type
61
(V+)_
Invert Zn6 Y/N
62
(N)_
3-18
4204/
ZONE
ENTRY
2-4204
TRIG.
2-
4204
only
2-
4204
only
2-
4204
only
2-
4204
only
4204
only
4204
only
4204
only
OPTIONS
[Y], [N]
Enables restore reporting for zone 3.
[01-15]
Defines the reporting delay in seconds for zone 3.
[00] = no delay
[Y], [N]
Reports alarms on zone 3 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to "Report
Only if Armed," skip to Prompt 60: "Enable Zn6."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone 4
trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 4.
[01-15]
Defines the reporting delay in seconds for zone 4.
[00] = no delay
[Y], [N]
Reports alarms on zone 4 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 8 in 2-
4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone 5
trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 5.
[01-15]
Defines the reporting delay in seconds for zone 5.
[00] = no delay
[Y], [N]
Reports alarms on zone 5 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 8 in 2-
4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
[Y], [N]
If [N], skip to Prompt 66: "Enable Zn7."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone 6
trigger; otherwise uses normal input signal.
DESCRIPTION