PROMPTS
Create Password?
4
Y/N_
Change Password?
5
Y/N_
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
Y/N_
Device Mode
9
(ECP)_
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the
communication device is triggered, a corresponding email message is sent INSTEAD of normal central station reports.
Cover tamper will send email event 8. All communication device system events (such as power loss, etc.) are still sent
to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to
events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central Station
reporting of critical events (alarms, troubles, etc.).
NOTE: The Multi-Mode option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
Multi Mode
10
(Disabled)_
4204/
ZONE
ENTRY
2-4204
TRIG.
[Y], [N]
[Y], [N]
[0-9, A-F, N,
S, T, X, Y]
[0-9, A-F, N,
S, T, X, Y]
[Y], [N]
[ESC]
• ECP
• Zone Trig.
• 4204 Emu
• Two 4204s
Important Information Regarding Multi-Mode
• Enabled
• Disabled
Section 3: Programming the 7847i/7847i-E
OPTIONS
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt
appears after pressing [N] at the "Program
Device?" prompt.
If a password is desired, press [Y] and go to
Prompt 6: "Enter Password."
If a password has already been assigned, this
prompt appears after pressing [N] at the
"Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key
when prompted for the new password and its
confirmation.
This prompt is displayed if [Y] was pressed in
Prompt 4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode
paragraph in this section.
Press the [space] key to scroll through the modes
of operation.
Press [ENTER] to select mode.
See Table 3 for ECP mode programming.
Enable if you want system events sent by email to
the user.
Disable for normal alarm processing and go to
Prompt 20: "Primary City ID".