8-16 Troubleshooting
Error
Error message
code
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS – SROM data read error.
0BB1
SMBIOS – SROM data checksum bad.
0BD1
1st SMBus device Error detected.
0BD4
2nd SMBus device Error detected.
0BD7
3rd SMBus device Error detected.
0BDA
4th SMBus device Error detected.
0BDD
5th SMBus device Error detected.
0BE0
6th SMBus device Error detected.
8068
Unsupported Processor Speed detected on
CPU Slot 1.
8069
Unsupported Processor Speed detected on
CPU Slot 2.
8150
NVRAM Cleared by Jumper
8151
Password Cleared by Jumper
8160
Mismatch Processor Type/Speed detected
on Processor 1.
8161
Mismatch Processor Type/Speed detected
on Processor 2.
None
Expansion ROM not initialized – PCI Mass
Storage Controller in slot n (n: slot number)
H/W Configuration of BMC is corrupted.
!! Update BMC F/W Configuration by
configuration tool !!
!! Refer to BMC configuration manual !!
Memory Scramble mode disabled
Recommended Action
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
Contact your service representative.
Contact your service representative.
Contact your service representative.
Start SETUP and provide setting again.
Start SETUP and set password again.
Contact your service representative.
Disable initialization of the optional device
expansion ROM by using the BIOS SETUP
utility (see Chapter 4).
Use the NEC EXPRESSBUILDER to
configure the remote management card
(see Chapter 6).
Contact your service representative.